Data Acquisition Remote Data Acquisition & Control (ADAM)
| ADAM |
 |
|
Advanced Data Acquisition & Control Modules Introduction Features
- 4011 -- Analog Input Module
- 4011D -- T/C Input Module with LED Display
- 4012 -- Analog Input Module
- 4013 -- Pt or Ni RTD
- 4014D-- Analog (Transmitter) Input Module with
LED Display
- 4015 -- 6 Channel RTD Module
- 4015T -- 6-channel Thermistor Module with Modbus
- 4016 -- Strain Gauge Input Module
- 4017 -- 8-Channel Analog Input Module
- 4017 -- 8 channel Analog Input Module
- 4018 -- 8-Channel Thermocouple Input Module
- 4018M -- 8-Channel Analog Input Data Logger
- 4018 -- 8-channel Thrmocouple Input Module with
Modbus
- 4019 -- 8-channel Universal Analog Input Module
- 4019plus -- 8-ch Universal Analog Input Module with Modbus
- 4021-D - 1 Channel Analog Output Module
- 4021-DE -1 Channel Analog Output Module (RoHS)
- 4022T -- Serial Base Dual Loop PI D Controller
- 4024 -- 4-channel Analog Output Module
- 4050 -- Isolated Digital Input Module
- 4051 -- 16-ch Isolated Digital Input Module with Modbus
- 4052 -- Isolated Digital Input Module
- 4053 -- 16-ch Digital Input Module
- 4055 -- 16-ch Isolated Digital I/O Module with Modbus
- 4056S -- 12-ch Sink Type Isolated Digital Output Module with Modbus®
- 4056SO -- 12-ch Source Type Isolated Digital Output Module with Modbus®
- 4060 -- Relay Output Module
- 4068 -- 8-ch Relay Output Module with Modbus
- 4069 -- 8-ch Power Relay Output Module with Modbus
- 4080 -- 2-ch Counter/Frequency Module
- 4080D -- Counter/Frequency Input Module with
LED Display
- 4117 -- Robust 8-ch Analog Input Module with Modbus
- 4118 -- Robust 8-ch Thermocouple Input Module with Modbus
- 4150 -- Digital I/O - 7in and 8 Out channels
- 4168 -- Relay Output Module - 8 Form A Relays
- 4500 -- PC-based Communication Controller
- 4501 -- Ethernet-enabled Communication Controller with 8-ch DI/O
- 4501D -- Ethernet-enabled Communication Controller with 8-ch DI/O and 7-segment LED
- 4510 -- RS-422/485 Repeater
- 4520 -- Isolated RS-232 to RS-422/485 Converter
- 4914V -- 4-ch Vlotage Input Surge Protection Module
- 6018 -- 8-channel Thermocouple Input w/DO
Module
-
ADAM Accessories
- ADAM 4500/5000 Utility Software
|
|
|
| Introduction
ADAM modules are compact, intelligent sensor-to-computer interface units designed specifically for reliable operation in harsh environments. Their built-in microprocessors, encased in rugged industrial grade plastic packages, let them provide intelligent signal conditioning, analog I/O, digital I/O and RS-485 communication.
Features
Remote Programmable Input Ranges
RS-232/RS-485 Conversion
If no RS-485 interface is available on the host computer, you can use the ADAM-4520 RS-232/RS-485 Converter. The ADAM converter and repeater modules automatically control the RS-485 bus direction, so software written for half-duplex RS-232 may be used without modification. RS-485 bus control is completely transparent to the user.
Network Expansion Each
ADAM 4510 repeater lets you add 32 ADAM modules to the network or extend the network by another 4000 feet (1.2 Km). You can connect up to 256 ADAM modules to a single RS-485 network.
Programming and Software
You can use any high-level language with ASCII-based string functions (such as BASIC, PASCAL or C) to communicate with ADAM modules. For example, the command and response for an analog input module would be: Command: #05 Response: > 4.834 The command requests the data stored by the module with address 05 (Hex). The module responds with 4.834 V.
Programming Example The following BASIC program demonstrates how to communicate with an ADAM-4011 Analog Input Module. It instructs the ADAM-4011 to measure a T-Type thermocouple then displays the result on screen.
10 OPEN "COM1: 9600, N, 8, 1, RS, CS, CD, DS" AS # 1 20 CMD $="#24100600" 30 PRINT #1, CMD$ ‘ADAM-4011 is configured to address 24H,T-type TC input, baud rate of 9600, engineering unit data format’ 40 CMD$="#24" 50 PRINT #1, CMD$ ‘Read analog input data’ 60 RESULT$=INPUT$ (5, #1) 70 PRINT "Temperature="; Result$ 80 CLOSE: END
Utility Software Easy-to-use menu-driven utility software makes configuration and calibration of ADAM modules a snap. It also includes a terminal emulation program so you can easily read from and write to ADAM modules. Working with ADAM modules is so simple, you will be up and running in no time.
Tough Industrial Design
No physical adjustments need be made, since all modules are 100% remotely configured by the host computer. Modules mount on a DIN rail, panel or in a piggyback stack. You make signal connections through plug-in screw-terminal blocks, ensuring simple installation, modification and maintenance. ADAM modules accept any unregulated power source between 10 and 30 VDC. They are protected against accidental power supply reversals and can be safely inserted or disconnected without causing disturbance to a running network.
|
|
|
|
|
 |